New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm

Product Details
Customization: Available
After-sales Service: Repair and Maintenance Services Available
Warranty: 5years
Still deciding? Get samples of US$ 190/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
8
Year of Establishment
1999-10-18
  • New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
  • New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
  • New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
  • New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
  • New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
  • New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
Find Similar Products

Basic Info.

Model NO.
34WA-G12
Air Tube Material
Plastics
Corrosion Durability
Ultrahigh
Operating Voltage
230 VAC
Noise Level
Low
Application Fields
Mechanical Engineering
Mounting
Ceiling Mount
Lifetime
5~10 years
Certification
RoHS, CE, CCC
Condition
New
Transport Package
Packing in Wooden Boxes
Trademark
Dunan
Origin
China
HS Code
8415102100
Production Capacity
500000/Year

Product Description

Product Introduction
DunAn fan coil products are divided into concealed type and surface-mounted type, where the concealed type incudes 2-rowcoil,3-row coil,3+1-row coil (4 tubes) and DC brushless motor, and the surface-mounted type includes horizontal-vertcalsurface-mounted type,cassette four-blow type, and cassette two-blow type, etc. All these products are made by high -qualityaccessories, thus featuring by advanced structure, efficient performance, low consumption and low noise, beautiful appearance,and easy to maintain.
New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfmHorizontal Concealed Series
· Low Noise
The design has selected high-quality galvanized steel rotor, which transmits air in streamline form through strict dynamic andstatic balanced adjustment, so as to reduce the production of vortex airflow and airflow friction noise as well as ensure stableand quite unit operation.
· Wide Application Scope
To achieve the best air-conditioning effect,selectthe unit of different air volumes and enthalpydifferences according to different cold loads anddifferent using requirements. DunAn low-noisehorizontal concealed fan coil unit is speciallydesigned to meet such requirements. This seriesproduct includes 2-row coil, 3-row coil, and DC type,which can maximally meet users' requirements andcreate the most comfort air-conditioning system.
 
New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
Horizontal Concealed Series
·Various Accessories
According to the requirements of different air-conditioning systems,the unit provide stainlesssteel or elongated water plate, various return airbellows,FPT rubber joint,water filter,andcontrollers with various functions for selection.The unit adopts ultra-thin design,with height ofonly 235 mm,can maximally meet the siteinstallation requirements of users.
· Reliability
1.The thermal insulation layer thickness of wideone-time forming condensate water plate is 7mm, completely preventing from condensation;2. High-quality oil bearing is selected,withoutrequiring to fill oil.
3. Hydrophilic aluminum fin,preventing fromcorrosion and mold, reducing wateraccumulation and improving the heat exchangeefficiency.

 
New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
Horizontal Concealed Series
New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
Model FP-34WA FP-51WA FP-68WA FP-85WA FP-102WA FP-136WA FP-170WA FP-204WA FP-238WA
A 445 575 675 735 835 1215 1265 1515 1755
B 472 602 702 762 862 1242 1292 1542 1782
C Standard water plate 678 808 908 968 1068 1448 1498 1748 1988
Elongated water plate 928 1058 1158 1218 1318 1698 1748 1998 2238
D Standard water plate 50 50 50 50 50 50 50 50 50
Elongated water plate 300 300 300 300 300 300 300 300 300
E 48 48 48 48 48 48 48 48 48
Horizontal Concealed Series
New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm1.High-efficiency dust removal: Purification efficiency of PM2.5 particles is ≥91%;
2.Comprehensive sterilization:Killing rate of various viruses is ≥ 99%; removal rate of harmful rate is ≥ 95%;
3.Free selection: Users can choose dust removal type(JDX), sterilization type (CHX) and composite type (dust removal +sterilization)(FHX) according to requirements;
4.Long-lasting energy saving: Small air resistance (≤20Pa), with the service life of more than 10 years;
5. Safe and simple: Single functional section, can be installed at the return air inlet of fan coil or in the return air ductindependently.
Surface-mounted Series
New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
Note:
Elegant appearance: Beautiful view
Saving space: Maximum thickness of 250mm
The standard control mode is three-speed switch control,with remote control and wire control optional
The vertical surface mounted type has up-air outlet type only
The horizontal surface mounted type has down-return air and front air outlet type only
Judgment criteria for left and right type of unit: Facing the return air inlet,if the connecting pipe is on the left, it is left type; other wise, it is right type;

 
Model FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204
Rated air volume
(mh)
H 510 680 850 1020 1360 1700 2040
M 384 510 638 765 1020 1275 1530
L 258 340 425 510 680 850 1020
Refrigerating capacity (W) H 2680 3640 4480 5350 7180 8950 10600
M 2270 3020 3770 4530 6040 7515 8350
L 1650 2170 2710 3250 4340 5420 6050
Heating capacity (W) H 4050 5400 6750 8100 10800 13500 16200
M 3240 4290 5370 6430 8580 10720 13380
L 2260 3000 3710 4450 5950 7450 9580
Power (W) H 51 62 71 94 124 152 188
Noise (dB(A)) H 39 41 43 45 46 48 50
Power supply 220-240V/1P/50Hz
Coll working pressure 1.6MPa
Inlet/outlet water pipe joint Rc3/4 (internal thread)
Condensate water Joint cp20mm
Water ftow (Kg /h) H 520 700 876 1050 1400 1750 1990
Water resistance (Kpa) H 5.9 11.9 19.7 31.9 37.8 24.2 29.4
Weight (Kg) 19 21 22 27 39 47 49
 Cassette Double-blow Fan Coil
New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
Note:
Km2 indicates cassette double-blow type unit;
Suitable for long and narrow space,such as corridor or long andnarrow living room or dining room; two-way air outlet design,guaranteeing uniform air flow;
No left/right type division of unit;
Equipped with condensate water lift pump (with lift of 700 mm) andremote control.

 
Model FP-34KM4 FP-51KM4 FP-68KM4 FP-85KM4 FP-102KM4 FP-136KM4 FP-170KM4 FP-204KM4 FP-238KM4
Rated air volume m' /h 340 510 680 850 1020 1360 1700 2040 2380
Refrigeatin g capacity (W) 1800 2700 3600 4500 5400 7200 9000 10800 12150
Heating capacity (W) 2 7 00 4050 5400 6750 8100 10800 13500 16200 17500
Piping size Inlet/outlet water pipe Rc3 /4(DN20)
Condensate
pipe
<ll20
W a t er  flow (kg/h) 350 520 700 860 1050 1400 1750 1990 2320
Wateres1stance  kpa 30 30 30 30 40 40 40 40 50
Input power W 37 52 62 76 96 134 152 189 228
Noise dB (A) 3 7 ,,;;39 41 43 ,s;:;45 46 48 5 0 52
Connection type Internal thread connection
Power supply       1/N/PE/AC 220V 50HZ      
Unit net
weight (kg)
Type 290 23 23 23 34 34 34 48 48 48
Type 390 23 23 23 34 34 34 48 48 48
Working pessure (Mpa) 16
Overall dimensions A*B 650 *650 650 *650 650 *650 850 *850 850 *850 850 *850 1050 *1050 1050 *1050 1050 *1050
L*S 570 *570 570 *570 570 *570 730 *730 730 *730 730 *730 930 *930 930 *930 930 *930
K*H 280 *616 280 *616 280 *616 440*77 6 440 *77 6 440 *77 6 640 *976 640 *976 640 *976
Optional AccessoriesNew Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm
- The accurate address of the building
 
- The application of the building

- The size of the building, such as the height of each floor?

- The drawing of the building

- The environment condition of the building, such as highest temperature in summer

- The working condition of the outdoor units

- The function of each room

- Which rooms need indoor units

- Is it an old building or new building

- If it is still not decorated

- Which kind of indoor units do you prefer according to the catalog

- What is the local power supply for your building
Customisation process
New Type 4-Way Cassette Chilled Water Fan Coil Unit (2 Pipes Type) -1600cfm

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier